Sourcing desk · South Jinqiao Area, Pudong, Shanghai sale@machinerychina.org +86 21 6044 5623

Knowledge base · Mining & minerals

Dependable Griffin Electric Submersible Pumps

67 words About 1 min read Published by YJMT
Dependable Griffin Electric Submersible Pumps

Photo: Warman centrifugal pump by Bernard S. Janse · CC BY 2.5 via Wikimedia Commons

Answer Griffin offers a complete line of electric submersibles. Whether it is clean water, gray water, or trash laden effluent, Griffin has the right pump for your application.

Griffin offers a complete line of electric submersibles. Whether it is clean water, gray water, or trash laden effluent, Griffin has the right pump for your application. Electric submersibles are available for flows as low as a few gallons per minute to 5,000 thousand gallons per minute, head conditions to several hundred feet, and up to 5 in. solids handling capacity.

Griffin Pump & Equipment, Inc. 866.770.8100 http://www.griffinpump.com/

Technical context from YJMT

Sizing an electric submersible dewatering pump

The text above is an archived manufacturer announcement. The notes below are ours: general guidance on this class of equipment, with no specification attributed to any named product.

Flow and head together, never separately

A pump has no single capacity. It has a curve relating the flow it delivers to the head it works against. Sizing means finding where that curve crosses the system's requirement — the static lift plus every friction loss in the discharge hose, bends and valves. A pump chosen on flow alone, then asked to lift higher than expected through a long small-bore hose, delivers a fraction of its rating and the operator concludes it is faulty.

Friction loss rises sharply as hose diameter falls. Increasing hose size is often cheaper and more effective than increasing pump size.

Solids handling

The three broad classes differ by what they will pass:

  • Clean water pumps — dewatering where the water is filtered or settled.
  • Grey water and drainage pumps — small suspended solids.
  • Trash and slurry pumps — designed for solids, with hardened wear parts and a much more open impeller. On a site sump full of sand and grit, a clean-water pump will erode within days.

Electrical and installation points

Confirm the supply — voltage, phase and available current — and the starter or control panel; direct-on-line starting of a large three-phase motor may not be permitted. Verify rotation on three-phase units: a pump running backwards still moves some water, so the symptom is poor performance rather than none.

Most submersibles rely on the pumped liquid for motor cooling. Running one part-submerged or dry, even briefly, is the most common way they are destroyed.

Sourcing desk

Need the machine, not just the theory?

Send the specification and destination port. You get a factory-direct price, lead time and shipping estimate within two business days.